0445
Velocity Loop Proportional Gain Overflow
Fanuc · Alpha i Series Servo Amplifier
Was bedeutet 0445 ?
This invalid parameter setting alarm indicates that the internal calculation value of the velocity loop proportional gain has overflowed. This typically occurs when the parameter setting for the proportional gain is excessively high, leading to calculation errors.
Häufige Ursachen
- Proportional term in the velocity control loop has exceeded its maximum allowable value.
- Sudden changes in motor speed.
- Inadequate velocity loop proportional gain (P04-10).
- High frequency noise in velocity feedback.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Use the function for changing the internal format of the velocity loop proportional gain to prevent overflow.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026