External Radiator Fin Cooling Fan Stopped
Fanuc · Alpha i series AC Servo Motor
Was bedeutet 601 ?
This alarm is issued when the fan motor responsible for cooling the external radiator fin of the inverter has failed. This fan is a consumable part. Failure can lead to inverter overheating and potential damage if not addressed.
Häufige Ursachen
- Fan motor for inverter radiator has failed
- Fan clogged with foreign matter
- Power connector of the fan is improperly connected
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check that the fan is not clogged with foreign matter
- 2
Check that the power connector of the fan is connected properly
- 3
Replace the fan or the entire servo amplifier module