Übersetzen...
410
Servo Position Error (Stop State)
Fanuc · Alpha i series AC Servo Motor
Was bedeutet 410 ?
The servo position error in the stopped state is larger than the value specified in parameter No.110. This indicates that the motor is not holding its commanded position accurately while stationary, possibly due to mechanical backlash or insufficient holding torque.
Häufige Ursachen
- Mechanical cause of large position error, such as backlash, loose coupling, or external force.
- Parameter No.110 (position error limit in stop state) is set too low for the application.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Inspect the mechanical system for any sources of position error (e.g., backlash, loose components, external forces).
- 2
If no mechanical cause is found, increase the value of parameter No.110 to a suitable limit.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc Alpha i series AC Servo Motor