SP0201

Duplicate Motor Number Setting (15i)

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

Was bedeutet SP0201 ?

The same motor number (other than 0) is set more than once in parameter No. 5841 for Series 15i. This creates a conflict in spindle motor identification, which can lead to control issues.

Häufige Ursachen

  • Duplicate motor number assigned in the system configuration (15i).
  • Two motors programmed with the same identifier.
  • Motor numbering conflict in the machine setup.
  • Software error preventing unique motor identification.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check parameter 5841 (Motor number of each spindle) — ensure each connected spindle has a unique motor number, and it is not set to 0.