Was bedeutet SP0027 ?

The position coder (encoder) feedback cable is disconnected or the sensor is faulty. This results in loss of position feedback, making position control impossible.

Häufige Ursachen

  • Position encoder cable is physically disconnected.
  • Encoder signal lines are damaged.
  • The encoder itself has failed.
  • Incorrect encoder type configured in CNC.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check physical connection of the encoder cable at both the motor and the amplifier.

  2. 2

    Measure encoder signal integrity (e.g., A, B, Z pulses) at amplifier terminals.

  3. 3

    Verify encoder resolution and type settings in CNC parameter P4-XX.

  4. 4

    Test encoder output using an oscilloscope if possible.