Übersetzen...
5

Voltage warning high

Danfoss · VLT 2800 Variable Speed Drive

Was bedeutet 5 ?

The DC bus voltage (VDC) has exceeded the 'Voltage warning high' limit. The motor continues to operate, but if the VDC remains high for 5-10 seconds, the inverter will trip with an Alarm 7 (Overvoltage). This can be caused by an excessively high supply voltage or fast motor deceleration with insufficient braking.

Häufige Ursachen

  • High incoming AC line voltage (L1, L2, L3) exceeding the drive's rated input voltage or transient spikes on the grid.
  • Regenerative energy from the motor (e.g., rapid deceleration, overhauling load) is flowing back into the DC bus and exceeding the internal voltage limits.
  • Incorrect braking resistor sizing or fault in the braking chopper circuit, preventing proper dissipation of regenerative energy.
  • Drive output connected to a motor with very high inertia that is coasting down too rapidly without braking.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    1. Measure the incoming AC line voltage (phase-to-phase) at terminals R, S, T and compare to the drive's rated input voltage; report any sustained overvoltage to facility maintenance.

  2. 2

    2. Verify drive deceleration ramps (P2-01, P2-02) are set appropriately for the load inertia, consider increasing ramp times to reduce regenerative energy.

  3. 3

    3. If an external braking resistor is installed, measure its resistance with an ohmmeter and compare to the specified value (P1-30); check connections to terminals BR+ and BR-.

  4. 4

    4. Check parameter P1-30 (Braking Resistor Ohms) and P1-31 (Braking Resistor Power) for correct configuration relative to the installed resistor.

  5. 5

    5. Monitor DC bus voltage (A01-01) in real-time during operation to identify when and under what conditions the warning triggers.

Alle Codes in diesem Handbuch durchsuchen (40)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Danfoss VLT 2800 Variable Speed Drive