Übersetzen...
F7042

Validation error of safety related operating mode

Bosch Rexroth · IndraDrive MPx02

Was bedeutet F7042 ?

This safety technology error indicates a problem during the validation of a safety-related operating mode on the IndraDrive MPx02. This means the drive cannot confirm the integrity or validity of the selected safe operating mode, preventing its activation or leading to an immediate safety stop.

Häufige Ursachen

  • Attempt to activate an invalid or uncommissioned safety operating mode.
  • Conflicting conditions or parameters for the selected safety operating mode.
  • Firmware incompatibility with the safety operating mode's logic.
  • Corruption of safety parameters related to operating modes.
  • Incorrect command sequence for activating the safety operating mode.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify that the desired safety operating mode has been properly commissioned and configured in the IndraDrive MPx02.

  2. 2

    Check all preconditions and interlocks for activating the specific safety operating mode, ensuring they are met.

  3. 3

    Review safety parameters associated with operating modes (e.g., S-0-0005 'Safety command value') for consistency and validity.

  4. 4

    Ensure the IndraDrive MPx02 firmware is compatible with the safety configuration.

  5. 5

    If an external safety PLC is used, verify its programming for selecting and validating safety operating modes.

Alle Codes in diesem Handbuch durchsuchen (99)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Bosch Rexroth IndraDrive MPx02