Safety related limited increment exceeded
Bosch Rexroth · IndraDrive MPx02
Was bedeutet F7010 ?
This safety technology error indicates that the actual position increment of the motor, as monitored by the safety function, has exceeded a defined safety-related limited increment threshold on the IndraDrive MPx02. This typically means the motor moved further than permitted in a safe monitored mode, triggering a safety stop.
Häufige Ursachen
- Incorrectly parameterized safety-related limited increment (e.g., S-0-0196) for the application.
- Loss of control due to incorrect speed loop tuning or mechanical issues.
- Encoder fault or noise leading to erroneous position feedback.
- Commanded motion exceeding the safety-monitored increment.
- Unexpected external force causing the axis to move beyond the allowed increment.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review and adjust the safety-related limited increment parameter (e.g., S-0-0196 'Limited increment position range') in the IndraDrive MPx02, ensuring it is appropriate for the application.
- 2
Check the tuning of the speed and position control loops for stability and accuracy.
- 3
Verify the motor encoder for correct and clean position feedback. Inspect wiring for noise or loose connections.
- 4
Analyze the machine's motion profile and ensure that commanded position changes do not exceed the set safety increment.
- 5
Inspect the mechanical system for any binding, excessive backlash, or external forces that could cause unintended movement.