Übersetzen...
xxxx 0011
Invalid Connection ID
Beckhoff · TwinSAFE Logic FB
Was bedeutet xxxx 0011 ?
The FSoE connection ID used in communication is invalid or does not match the expected ID configured in the devices. This prevents the establishment or continuation of a secure safety connection, rendering the system inoperable due to a breakdown in trusted communication.
Häufige Ursachen
- Invalid Connection Identifier (ID) received.
- Attempted to communicate with a non-existent or wrong device ID.
- Network configuration error.
- Incorrectly assigned communication address.
- Duplicated Connection IDs on the network.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the FSoE connection ID is correctly configured and identical on both the master and slave devices.
- 2
Check the network topology and ensure no duplicate FSoE connection IDs exist within the safety domain.
- 3
Reinitialize the FSoE connection to ensure IDs are properly synchronized.
- 4
Consult the device manual for specific FSoE connection ID setup procedures.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Beckhoff TwinSAFE Logic FB