Übersetzen...
FB TWOHAND Bit 2

Two-Hand Discrepancy Error - Between Pairs

Beckhoff · TwinSAFE Logic FB

Was bedeutet FB TWOHAND Bit 2 ?

A discrepancy has been detected between the actuation times of input pair 1 and input pair 2 for the FB TWOHAND. This means the operator is not actuating both hands simultaneously within the allowed time window, or there's an issue with the timing of the two-hand control device itself. This fault ensures true simultaneous actuation for safety and stops the machine.

Häufige Ursachen

  • Operator actuation technique: one hand consistently actuates significantly before the other hand.
  • Mechanical binding or slow response of one two-hand button assembly compared to the other.
  • Excessive discrepancy time configured between input pairs (e.g., P_BetweenPairDiscTime) is too short for the application or operator.
  • Voltage drop or intermittent connection affecting the response time of one entire input pair.
  • Slight variation in switch bounce characteristics between the two separate input pair buttons.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    1. Observe the operator's hand placement and simultaneous actuation technique, providing retraining if necessary to ensure both buttons are pressed concurrently.

  2. 2

    2. Measure the actuation and release times of each two-hand button assembly using a timing device or oscilloscope connected to the input terminals (e.g., X5.1 and X5.3).

  3. 3

    3. Access the safety controller's programming interface and adjust the 'BetweenPairDiscTime' parameter (e.g., increase from 200ms to 350ms) to accommodate operator variance.

  4. 4

    4. Verify the integrity of the 24VDC supply voltage to both two-hand button assemblies, checking for drops below 22VDC during actuation.

  5. 5

    5. Check and clean the electrical contacts within both two-hand button assemblies for any foreign material that could impede consistent response.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes