Übersetzen...
4633

Wire break in phase B

Beckhoff · TwinCAT 2 NC

Was bedeutet 4633 ?

A wire break (loss of continuity) has been detected or reported in phase B of the motor connection, either within the drive or at the terminal. This critical fault means one of the motor phases is open-circuited. Attempting to operate the motor with a phase break can lead to severe damage to both the motor and the drive due to unbalanced currents.

Häufige Ursachen

  • Open circuit in the motor power cable for phase B between the drive output terminal (e.g., V) and the motor terminal.
  • Loose or corroded connection at the drive output terminal V or the corresponding motor terminal (e.g., T2).
  • Internal winding break in phase B of the motor, preventing current flow.
  • Faulty motor contactor or relay with an open contact for phase B in the motor power path.
  • Drive's internal current sensor for phase B (e.g., R0-05) malfunctioning or reporting zero current despite motor operation.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Power down the drive and motor, then measure the resistance of the motor cable phase B (e.g., from drive terminal V to motor terminal B/T2) using an ohmmeter to confirm continuity.

  2. 2

    Disconnect the motor cable from both the drive output (V) and the motor input (B/T2), then visually inspect and retighten all connections.

  3. 3

    Measure the resistance of the motor windings (e.g., U-V, V-W, W-U) at the motor terminals; an open circuit on one phase (e.g., V-U infinite, V-W infinite) indicates an internal motor fault.

  4. 4

    If a motor contactor is used, check its contacts for continuity across phase B (e.g., terminals 3-4) with the contactor energized and de-energized.

  5. 5

    Temporarily swap the motor phase B and C connections at the drive (connect motor Phase B cable to drive W, motor Phase C cable to drive V) and observe if the fault shifts to 'Wire break in phase C'.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Beckhoff 4633 Wire break in phase B: Fehleranalyse & Ursach… | ErrorLib