Übersetzen...
4010

Channel identifier not allowed

Beckhoff · TwinCAT 2 NC

Was bedeutet 4010 ?

An unacceptable value (outside the range of 1 to 255) has been used for a channel identifier, or the specified channel does not exist within the current system configuration. This parameter error prevents proper identification and control of the specified channel, leading to operational failure or incorrect routing of commands.

Häufige Ursachen

  • Invalid channel number specified in the NC program (e.g., G-code), PLC command, or HMI interface (outside 1-255).
  • Configuration parameter P3-01 ('Number of Channels') is set incorrectly or below the desired channel ID.
  • Attempting to access an NC channel that has not been defined or enabled in the current NC configuration.
  • Firmware inconsistency or bug where channel IDs are misinterpreted or validated incorrectly.
  • Programming error in the HMI or PLC sending an out-of-range channel ID to the NC controller.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    1. Review the NC program or PLC logic that initiated the command and correct the channel identifier to a valid range (1-255).

  2. 2

    2. Verify the NC configuration parameter P3-01 ('Number of Channels') matches the actual number of configured channels.

  3. 3

    3. Check the channel mapping in the NC setup (e.g., System Configuration menu > Channels) to confirm the existence of the specified channel.

  4. 4

    4. Reload the correct NC configuration file from a verified backup to ensure proper channel definitions.

  5. 5

    5. Debug the HMI or PLC interface sending the channel identifier to ensure it respects the NC's defined range.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes