90

Encoder Quadrature Error

Allen-Bradley · PowerFlex 700

Was bedeutet 90 ?

Both encoder channels (A and B) changed state within a single clock cycle. This suggests an issue with the encoder signal quality, possibly due to electrical noise or a damaged encoder, causing incorrect speed or position feedback.

Häufige Ursachen

  • Encoder signals A and B are reversed or swapped.
  • Encoder pulses are inconsistent or noisy.
  • Incorrect encoder resolution set in drive parameters (e.g., P4-01).
  • Faulty encoder or internal logic issue.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check for externally induced noise on encoder cabling (e.g., proximity to power cables, proper shielding and grounding).

  2. 2

    Replace the encoder unit.