79

Excessive Load

Allen-Bradley · PowerFlex 700

Was bedeutet 79 ?

The motor did not come up to speed in the allotted time during an autotune procedure. This indicates the motor or connected load is preventing the autotune from completing successfully, potentially due to high friction or an oversized load.

Häufige Ursachen

  • Mechanical system connected to the drive is experiencing a high load.
  • Application demanding more torque than the motor can deliver.
  • Incorrect motor sizing for the application.
  • Faulty coupling or gearbox causing increased drag.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Uncouple the mechanical load from the motor.

  2. 2

    Repeat the Autotune procedure.