Übersetzen...
4310

Motor Overtemperature

ABB · ACS800 Standard Firmware

Was bedeutet 4310 ?

The motor temperature is excessively high, or appears high, due to factors such as excessive load, insufficient motor power for the application, inadequate motor cooling, or incorrect drive start-up data. Sustained overtemperature operation risks motor winding damage and premature failure.

Häufige Ursachen

  • Motor temperature has exceeded its safe operating limit.
  • Overload condition causing motor overheating.
  • Inadequate motor cooling (e.g., blocked fan).
  • High ambient temperature affecting motor.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check motor ratings and compare them against the actual mechanical load of the application.

  2. 2

    Verify the motor's cooling system, including checking the cooling fan operation and cleaning any clogged cooling surfaces.

  3. 3

    Review drive start-up data parameters, particularly those in parameter group 99 (START-UP DATA), for accuracy against the motor nameplate.

  4. 4

    Check Fault Function parameters 30.04 to 30.09 related to motor temperature supervision for correct configuration.

Alle Codes in diesem Handbuch durchsuchen (33)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes