F3147

System error channel 1

Bosch Rexroth · IndraDrive MPx02

What does F3147 mean?

A system error has been detected in safety channel 1. This indicates a failure or discrepancy within the primary safety processing path of a redundant safety system. Similar to a channel 2 error, this redundancy failure means the system cannot guarantee its safety integrity, leading to a fault state and requiring immediate attention.

Common Causes

  • Hardware fault in safety channel 1's processing unit
  • Software error affecting channel 1's execution
  • Interference or noise affecting channel 1's signals
  • Discrepancy between channel 1 and channel 2 outputs/inputs
  • Power supply issue specific to safety channel 1

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect all safety-related wiring and connections to the IndraDrive's safety channel 1 inputs for damage, loose terminals, or proper shielding.

  2. 2

    Measure the voltage levels of the safety channel 1 input signals (e.g., STO inputs, safety gate feedback) at the IndraDrive terminals, verifying they align with the expected safe or unsafe state.

  3. 3

    Verify the 24VDC control voltage supply to the safety module or safety input terminals of the IndraDrive against specifications, checking for stability and correct levels.

  4. 4

    Review the IndraDrive's safety-related parameters and diagnostic registers for channel 1 to ensure correct configuration and identify any reported internal discrepancies.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive MPx02