F8060

Fatal Error (Operation)

Bosch Rexroth · IndraDrive C Drive Controllers

What does F8060 mean?

This is a fatal error encountered during drive operation. When F8060 occurs, the closed-loop or open-loop U/f control of the drive is no longer guaranteed. The drive immediately switches off, becoming torque-free, overriding settings in P-0-0119 and P-0-0117.

Common Causes

  • An unspecified error condition detected during the operational phase of the drive.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Clear the error message using command S-0-0099 (C0500 Reset class 1 diagnostics). This may require switching to parameter mode or a complete drive power cycle.

  2. 2

    Ensure the drive is in operating mode and power is switched on ("Ab").

  3. 3

    Switch on drive enable again (0-1 edge).

  4. 4

    If this fatal error recurs repeatedly, replacement of an entire component (e.g. motor or drive controller) may be necessary.

Browse all codes in this manual (6)
Verified technical data. Last updated: March 2026

Related Faults

Source: Bosch Rexroth IndraDrive C Drive Controllers