FB ESTOP Bit 0

E-Stop Discrepancy Error - Input Group 1

Beckhoff · TwinSAFE Logic FB

What does FB ESTOP Bit 0 mean?

A discrepancy has been detected between the two channels of input group 1 for the FB ESTOP. This indicates that the redundant E-Stop input signals are not in agreement, suggesting a potential failure of one channel, a wiring issue, or an incorrect switching sequence. This will prevent the E-Stop function from operating safely and halt the machine.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Review the discrepancy time parameter for E-Stop input group 1 in the FB ESTOP configuration; adjust if the application legitimately has different timing requirements.

  2. 4

    Monitor the individual input channels for group 1 in real-time using diagnostics to identify which channel is deviating or delayed.

Source: Beckhoff TwinSAFE Logic FB