F152
Channel Errors
Beckhoff · AX5000 Servo Drive
What does F152 mean?
This error indicates a problem within one of the drive's channels. If it's the only error displayed on a two-channel device, the fault likely lies in the other channel, requiring focused troubleshooting there. Otherwise, it's a general channel error necessitating further investigation based on other active diagnostic messages. This fault can also be a secondary error stemming from an incorrect P-0-0150 setting, often accompanying F4A5, preventing proper operation.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
If F4A5 (SoE Communication Parameter Error) is also present, investigate and correct issues related to parameter P-0-0150 first, as F152 might be a consequence of that primary error.
Source: Beckhoff AX5000 Servo Drive