F40
Phase W to Gnd
Allen-Bradley · PowerFlex 4 Adjustable Frequency AC Drive
What does F40 mean?
A grounded phase condition has been detected specifically on motor phase W or in the wiring connecting drive output terminal W to the motor. This indicates a direct short path to ground.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Measure insulation resistance between motor phase W and the motor frame using a megger at 500VDC; expect a reading greater than 1 MΩ.
- 4
Inspect the wiring connecting drive output terminal W and motor phase W for any physical damage or signs of insulation breakdown.
Source: Allen-Bradley PowerFlex 4 Adjustable Frequency AC Drive
Open Manual (Page 15)