30032
Hardware revision does not support EPL (_ecHARDWARE_DOES_NOT_SUPPORT_EPL)
ABB · ACS850 Standard Program Firmware
What does 30032 mean?
This error indicates that the drive's hardware revision does not support Ethernet POWERLINK (EPL). Specifically, earlier e180 drives with GCU-01 control cards before Revision A lack EPL support. If the EPL address switches are not set to '0' on such hardware, this error will be generated. While the drive may function in other modes, EPL functionality will be unavailable, requiring a hardware upgrade if EPL is essential.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
If Ethernet POWERLINK functionality is required and the hardware does not support it, the drive hardware will need to be exchanged for a compatible revision.
Source: ABB ACS850 Standard Program Firmware