10040

Hiperface DSL encoder error

ABB · ACS850 Standard Program Firmware

What does 10040 mean?

An error has occurred while attempting to read position data over the Hiperface DSL interface. This suggests a problem with the feedback device wiring, the motor connector, or connections inside the adapter, which can lead to inaccurate or lost position information, affecting motor control and synchronization.

Additional Steps

Steps 1–2 are listed in Priority Fix.

  1. 3

    Ensure all earthing and shielding are correctly implemented as per the drive installation manual.

  2. 4

    Reduce your application's speed to determine if the error is related to communication bandwidth or signal integrity at higher speeds.

  3. 5

    Connect to the drive with Mint Workbench and navigate to 'Parameters > Encoder > Channel 0 > Encoder Parameter(Encoder0, Fault Register)'. If this contains a value other than 0, consult the help file for 'ENCODERPARAMETER' for more specific diagnostic information.

Source: ABB ACS850 Standard Program Firmware